防爆接線箱|BJX防爆接線箱|防爆電纜分線箱-樂清威創(chuàng)防爆科技有限公司專業(yè)生產(chǎn); 
殼體型號 型號 A B C D E 進線口數(shù)量及規(guī)格 出線口數(shù)量及規(guī)格 備注 Ⅰ型 BJX-20/4 200 185 100 140 100 1-G3/4" 4-G1/2" ExdⅡBT6 Ⅱ型 BJX-20/8 242 215 136 164 112 1-G1" 7-G3/4" Ⅲ型 BJX-20/16 324 280 214 235 132 1-G1/2" 7-G3/4" Ⅳ型 BJX-20/24 422 286 316 235 132 1-G1/2" 11-G3/4" Ⅴ型 BJX-20/36 422 359 320 315 134 1-G1/2" 13-G3/4" 殼體型號 型號 A B C D E F 進線口數(shù)量及規(guī)格 出線口數(shù)量及規(guī)格 備注 Ⅰ型 BJX-20/8 270 290 160 160 113 99 1-G3/4" 6-G1/2" ExdⅡCT6 Ⅱ型 BJX-20/16 330 360 220 220 119 104 1-G11/2" 6-G3/4" Ⅲ型 BJX-20/24 370 408 260 260 135 119 1-G1/2" 10-G3/4" Ⅳ型 BJX-20/36(48) 460 498 350 350 140 124 1-G1/2" 12-G3/4"
殼體型號 型號 A B C D E F G H 進線口數(shù)量及規(guī)格 出線口數(shù)量及規(guī)格 備注 Ⅰ型 BJX-20/20 190 226 274 92 124 238 12 98 1-G1" 3-G3/4" ExeⅡT6 Ⅱ型 BJX-20/20 190 226 318.5 150 190 332 12 98 1-G11/2" 3-G1" Ⅲ型 BJX-20/30 250 210 378.5 190 226 332 12 98 1-G1/2" 4-G1" Ⅳ型 BJX-20/60 250 351 400 210 250 404 13 98 1-G2" 6-G1" Ⅴ型 BJX-20/80 300 351 428.5 160 200 354 13 98 2-G2" 7-G1" Ⅵ型 BJX-20/120 300 351 429 260 300 454 13 98 2-G2" 9-G1"
1.防爆接線箱|BJX防爆接線箱|防爆電纜分線箱用途與適用范圍 1 Purpose and scope BJX51防爆接線箱(防爆分線箱)是根據(jù)國家標準GB3836.1—2000《爆炸性氣體環(huán)境用電氣設(shè)備 第1部分:通用要求》和GB3836.2—2000《爆炸性氣體環(huán)境用電氣設(shè)備 第2部分:隔爆型“d”》的要求設(shè)計與制造的,主要用于爆炸性氣體環(huán)境中1區(qū)或2區(qū)危險區(qū)域,為ⅡB類T6組及以下的爆炸危險場所,在交流50Hz、額定電壓至380V、額定電流至200A的電路中,作為照明、信號、動力電線電纜連接和分支之用。 BJX51 explosion-proof junction box (explosion-proof junction box) is based on the national standard GB3836.1 - 2000 "electrical apparatus for explosive gas atmospheres - part first: General requirements" and GB3836.2 2000 "electrical apparatus for explosive gas atmospheres - Part second: Flameproof Enclosures" d "requirements of the design and manufacturing, mainly used in explosive gas environment Zone 1 or zone 2 hazardous area, for class Ⅱ B and below T6 group explosive dangerous location, in the circuit of AC 50Hz, rated voltage to 380V, rated current up to 200A, as the lighting, signal, power wire and cable connection and branch of. 2.防爆接線箱|BJX防爆接線箱|防爆電纜分線箱產(chǎn)品型號含義及基本參數(shù) The 2 model the meaning and basic parameters 2.1產(chǎn)品型號含義 The 2.1 model the meaning B JX-□\/□T□\/□L□\/□B□\/□R□\/□ B JX □ □ □ □ \ / T / L / □ □ □ □ B / R / □ □ 進線口數(shù)\/螺紋 The incoming line port number \ / thread 右方進線 Right in line 進線口數(shù)\/螺紋 The incoming line port number \ / thread 下方進線 Below the line 進線口數(shù)\/螺紋 The incoming line port number \ / thread 左方進線 The left line 進線口數(shù)\/螺紋 The incoming line port number \ / thread 上方進線 The top line 額定電流 Rated current 端子數(shù) The number of terminals 接線箱 Junction box 隔爆型 Flameproof 2.2基本參數(shù)(見表) 2.2 basic parameters (see table) 型號 額定電壓 Types of rated voltage (V) 額定電流 Rated current (V) (A) 防爆標志 防護等級 (A) explosion-proof mark protection grade BJX-6 380、220 10~200 ExdⅡBT6 IP54 BJX-6 380, 22010 ~ 200 Exd II BT6 IP54 BJX-12 BJX-12 BJX-36 BJX-36 選型指南 Selection Guide 注:1、訂貨時請注明所需產(chǎn)品的防爆型式。 Note: 1, when ordering please specify the type of protection required products. 例: Cases: 1、若需訂購BJX防爆接線箱,防爆型式為ⅡC級、額定電流為20A、接線端子數(shù)為8、上方有2個G3\/4"引入口、左方有2個G3\/4" 1, if you need to order the BJX explosion-proof junction box, explosion-proof type II C, rated current is 20A, terminal number is 8, above the 2 G3\/4 "into the mouth, the left has 2 G3\/4" 2、若需訂購BJX粉塵防爆接線箱,額定電流為20A、接線端子數(shù)為36、上方有5個G3\/4"引入口、左方有3個G3\/4"引入口、下方有2個G1"引入口和2個G3\/4"引入口、右方有3個G3\/4"引入口,則訂貨型號為“BJX-DIP-20\/36D5(G3\/4)\/L3(G3\/4)\/X2(G1)2(G3\/4)\/R3(G3\/4)” 2, if you need to order the BJX dust explosion-proof junction box, rated current is 20A, terminal number is 36, above the 5 G3\/4 "into the mouth, the left has 3 G3\/4" into the mouth, below the 2 G1 "into the mouth and 2 G3\/4" into the mouth, the right has 3 G3\/4 "into the mouth, then ordering model for" BJX-DIP-20\/36D5 (G3\/4) \/L3 (G3\/4) \/X2 (G1) 2 (G3\/4) \/R3 (G3\/4)" BXJ-124-190 進出口為3\/4 BXJ-124-190 import and export as 3\/4 BXJ-190-190 進出口為3\/4 BXJ-190-190 import and export as 3\/4 3.防爆接線箱|BJX防爆接線箱|防爆電纜分線箱接線箱在下列條件下能夠可靠工作 3 junction box can work reliably under the following conditions a)安裝地點的海拔不超過2000m; A) installation site elevation not exceeding 2000m; b)周圍空氣溫度上限值不超過+40℃,下限值不低于-20℃,且24h內(nèi)平均值不超過+35℃; B) the temperature of the air around the upper limit of not more than +40 ℃, lower value not lower than -20 ℃, and the 24h average value not more than +35 ℃; c)安裝地點的空氣相對濕度在zui高溫度為+40℃時,不超過50%;在較低的溫度下允許有較高的相對濕度,zui濕的月平均zui低溫度不超過+25℃,該月的月平均zui大相對濕度不超過90%; C) the installation site of the air relative humidity at the highest temperature of +40 ℃, not more than 50%; allow a higher relative humidity in the lower temperature, the humidity of the monthly mean minimum temperature of not more than +25 DEG C, the monthly average maximum relative humidity of not more than 90%; d)污染等級為3級。 D) pollution grade was 3. e)安裝類別為Ⅱ類。 E) installation for the type of category. 4.防爆接線箱|BJX防爆接線箱|防爆電纜分線箱主要結(jié)構(gòu) The 4 main structure 接線箱采用鑄鋁合金制成,隔爆型結(jié)構(gòu),腔內(nèi)裝有接線端子或母線排,設(shè)有內(nèi)外接地螺釘,供接地線連接。電纜引入裝置內(nèi)從內(nèi)到外依次裝有密封圈、墊圈和壓緊螺母適合電纜和鋼管布線。接線箱的外表面靜電粉末噴塑,耐腐蝕。 Junction box is made of aluminum alloy, flameproof structure, cavity is provided with a wiring terminal or bus, with internal and external grounding screw, for grounding wire. Cable introducing device from the inside to the outside is provided with a sealing ring, gasket and nut for cable and steel pipe wiring. The outer surface of electrostatic powder spray box, corrosion resistance. 5.使用與維修 5 use and repair 5.1安裝時,將接線箱蓋和引入裝置打開,根據(jù)電纜的外徑選擇合適的密封圈內(nèi)徑尺寸,然后把電纜依次穿過引入裝置的壓緊螺母、墊圈和密封圈接至腔內(nèi),緊固壓緊螺母使電纜密封,不引入電纜的引入裝置用堵棒代替電纜,并緊固好壓緊螺母。把導線接至接線端子的相應(yīng)位置上,接好接地線,合上蓋,把蓋用螺栓緊固即可使用; 5.1 installation, the junction box cover and introducing device is opened, according to the outer diameter of cable selection of sealing ring diameter of suitable size, and then followed by cable through the introduction of device hold-down nut, the gasket and sealing ring is connected to the cavity, fastening nut so that the cable sealing, introducing device does not introduce cable with plug rod to replace the cables, and fastening nut. The corresponding position of a wire connected to the terminals, connect the ground wire, close the cover, the cover can be used with bolts; 5.2 接線箱不得隨意拆卸,維修時先斷開前級電源后,才能開蓋維修,維修時不得損壞隔爆接合面,維修后隔爆接合面清理后涂204-1防銹油,將蓋合好后,各部分螺栓(釘)緊固后才能使用; 5.2 junction box shall not disassemble, repair to disconnect the power supply before class, to open repair, repair shall not be damaged flameproof joint, after the repair of flameproof joint after cleaning with 204-1 antirust oil, will cover together, each part of the bolt (screw) fastening to use; 5.3 接線箱應(yīng)定期檢查,發(fā)現(xiàn)電纜引入裝置的密封圈老化變質(zhì)及其他零件損壞應(yīng)及時更換。 5.3 junction box should be checked regularly, found that cable introducing device of the ring aging deterioration and other parts damaged should be replaced promptly. 專業(yè)生產(chǎn):防爆配電箱,鑄鋁防爆箱,不銹鋼防爆箱,防爆接線箱,防爆照明配電箱,防爆動力配電箱,防爆配電柜,防爆控制箱,BZC51防爆操作柱,防爆應(yīng)急燈,防爆熒光燈,防爆無極燈廠家,防爆正壓柜,防爆投光燈,柳市防爆箱,防爆斷路器等,質(zhì)量三包,凡購買本公司產(chǎn)品,質(zhì)保三年,本公司證件齊全,價格實惠! www.shbxmd.com www.zj8899.com www.jiang-ex.com www.fangbaoa.com www.zj-88.com www.wcfangbao.com www.exbaidu.com www.wzfangbao.com |